Description
- Branch office remote client device
- SIP-protocol terminal adapter
Capacity
Handset Interoperability
In EXTender mode, the IP6000 supports the following handsets:
- Avaya: Definity and Merlin Magix™
- Nortel: Meridian® and Norstar®
In TVA mode, the IP6000 supports numerous handset types in addition to the above list, including:
- NEC Dterm/Dterm I
- Panasonic DBS
- Siemens Hicom
- Toshiba Strata DK
PBX/KTS Interoperability
The EXTender IP6000 supports leading PBX platforms, including:
- Avaya: Definity® Ecs & Merlin Magix™
- Nortel: Meridian, Norstar, and BCM
IP PBX Interoperability
The Citel EXTender IP6000 interoperates with leading IP PBX platforms, including::
- Asterisk
- Avaya Communication Manager with SIP Enablement Server
- Broadsoft
- Sylantro
Citel Equipment Interoperability
- PBXgateway I
- PBXgateway II
Enhanced Features
- Software upgradeable to SIP Portico TVA configuration
- Active Call Monitoring (Norstar only)
- Advanced ACD function support
- Analog port for 911 calls
Interfaces
- 10/100 Ethernet RJ-45
- RJ-11 Analog
- 12 Digital Lines over 25-pair RJ-21
Voice Protocols
Supports voice compression standards::
- G.729A
- G.726 (24 or 32 kbps ADPCM)
- G.711
- Citel Remote Voice Protocol over Internet Protocol (RVPoIP)
|
|
Configuration & Management
- In EXTender mode, up to two IP6000s can be terminated into one PBXgateway or PBXgateway II over serial RVP connections.
- In Handset Gateway mode, there are no PBXgateways in the configuration.
Supported Utilities:
- RS-232 serial connection to PC
- LAN Telnet
- HTML
- PC and modem connection
- Phone display (limited features)
- SNMP support (Citel MIBs and traps)
Software Support
- TCP/IP support for IP traffic and management access.
- RVPoIP uses UDP/IP protocol for voice transmission.
Physical
- Form Factor: Low Profile, 1U rack mountable unit
- Size: 17” x 8” x 1¾” (432mm x 203mm x 44mm)
- Weight: 6.7 lbs (3.1 kg)
Power
- Universal auto ranging
- Voltage requirement: 12 VDC
- Frequency: 50 – 60 Hz
- Maximum power draw: 16 Watts
Environmental
- Temperature: 32 - 130 F (0 - 55 C)
- Relative humidity: 5 - 95%
(non-condensing)
Regulatory
- FCC
47 CFR Part 15 Class B
47 CFR Part 68 US
- CE EN55024+A1/A2
EN6100-3-2
EN6100-3-3
- Industry Canada CS-03
387B-EXT6001
- Safety UL60950-1
C22-2 No60950-1
EN60950-1
IEC60950-1
Warranty
- One-year limited warranty for parts & labor.
- Extended warranty options available.
|